ShuntCompensator
A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor. A negative value for bPerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device. Ground is implied.
*NOTE: this is an abstract class and should not be instantiated directly
URI: cim:ShuntCompensator
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class ShuntCompensator
click ShuntCompensator href "/Models/Profiles/Equipment/AbstractClasses/ShuntCompensator/"
style ShuntCompensator fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ShuntCompensator <|-- LinearShuntCompensator : inherits
LinearShuntCompensator
click LinearShuntCompensator href "/Models/Profiles/Equipment/ConcreteClasses/LinearShuntCompensator/"
style LinearShuntCompensator fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
RegulatingCondEq <|-- ShuntCompensator : inherits
click RegulatingCondEq href "/Models/Profiles/Equipment/AbstractClasses/RegulatingCondEq/"
style RegulatingCondEq fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConnection <|-- RegulatingCondEq : inherits
click EnergyConnection href "/Models/Profiles/Equipment/AbstractClasses/EnergyConnection/"
style EnergyConnection fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment <|-- EnergyConnection : inherits
click ConductingEquipment href "/Models/Profiles/Equipment/AbstractClasses/ConductingEquipment/"
style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- ConductingEquipment : inherits
click Equipment href "/Models/Profiles/Equipment/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/Equipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/Equipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
RegulatingCondEq --> RegulatingControl : RegulatingCondEq.RegulatingControl
RegulatingControl
click RegulatingControl href "/Models/Profiles/Equipment/ConcreteClasses/RegulatingControl/"
style RegulatingControl fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage
BaseVoltage
click BaseVoltage href "/Models/Profiles/Equipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/Equipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> AssetInfo : PowerSystemResource.AssetDataSheet
AssetInfo : Not defined in profile
AssetInfo
style AssetInfo fill:#A9A9A9,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/Equipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Terminal --> ConductingEquipment : Terminal.ConductingEquipment
Terminal
click Terminal href "/Models/Profiles/Equipment/ConcreteClasses/Terminal/"
style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> LocationMethodKind : PowerSystemResource.locationMethodKind
LocationMethodKind
click LocationMethodKind href "/Models/Profiles/Equipment/Enumerations/LocationMethodKind/"
style LocationMethodKind fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ShuntCompensator : ShuntCompensator.aVRDelay
ShuntCompensator : ShuntCompensator.maximumSections
ShuntCompensator : ShuntCompensator.nomU
ShuntCompensator : ShuntCompensator.normalSections
RegulatingCondEq : RegulatingCondEq.RegulatingControl
ConductingEquipment : ConductingEquipment.BaseVoltage
Equipment : Equipment.aggregate
Equipment : Equipment.normallyInService
Equipment : Equipment.EquipmentContainer
PowerSystemResource : PowerSystemResource.locationMethodKind
PowerSystemResource : PowerSystemResource.AssetDataSheet
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.name
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EnergyConnection
- RegulatingCondEq
- ShuntCompensator
- RegulatingCondEq
- EnergyConnection
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
aVRDelay | cim:ShuntCompensator.aVRDelay | 0..1 Seconds | An automatic voltage regulation delay (AVRDelay) which is the time delay from a change in voltage to when the capacitor is allowed to change state. This filters out temporary changes in voltage. | direct |
maximumSections | cim:ShuntCompensator.maximumSections | 0..1 integer | The maximum number of sections that may be switched in. | direct |
nomU | cim:ShuntCompensator.nomU | 0..1 Voltage | The voltage at which the nominal reactive power may be calculated. This should normally be within 10% of the voltage at which the capacitor is connected to the network. | direct |
normalSections | cim:ShuntCompensator.normalSections | 1..1 integer | The normal number of sections switched in. The value shall be between zero and ShuntCompensator.maximumSections. | direct |
RegulatingControl | cim:RegulatingCondEq.RegulatingControl | 0..1 RegulatingControl | The regulating control scheme in which this equipment participates. | RegulatingCondEq |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage | Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean | The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean | The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer | Container of this equipment. | Equipment |
locationMethodKind | nc-no:PowerSystemResource.locationMethodKind | 0..1 LocationMethodKind | Possible methods to derive geographical location. | PowerSystemResource |
AssetDataSheet | cim:PowerSystemResource.AssetDataSheet | 0..1 AssetInfo | Datasheet information for this power system resource. | PowerSystemResource |
mRID | cim:IdentifiedObject.mRID | 0..1 string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject |
description | cim:IdentifiedObject.description | 0..1 string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
name | cim:IdentifiedObject.name | 0..1 string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
Schema Source
- from schema: https://ap-no.cim4.eu/Equipment/1.0