Disconnector
A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made.
URI: cim:Disconnector
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class Disconnector
click Disconnector href "/Models/Profiles/Equipment/ConcreteClasses/Disconnector/"
style Disconnector fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Switch <|-- Disconnector : inherits
click Switch href "/Models/Profiles/Equipment/AbstractClasses/Switch/"
style Switch fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment <|-- Switch : inherits
click ConductingEquipment href "/Models/Profiles/Equipment/AbstractClasses/ConductingEquipment/"
style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- ConductingEquipment : inherits
click Equipment href "/Models/Profiles/Equipment/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/Equipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/Equipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage
BaseVoltage
click BaseVoltage href "/Models/Profiles/Equipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/Equipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> AssetInfo : PowerSystemResource.AssetDataSheet
AssetInfo : Not defined in profile
AssetInfo
style AssetInfo fill:#A9A9A9,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/Equipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Terminal --> ConductingEquipment : Terminal.ConductingEquipment
Terminal
click Terminal href "/Models/Profiles/Equipment/ConcreteClasses/Terminal/"
style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> LocationMethodKind : PowerSystemResource.locationMethodKind
LocationMethodKind
click LocationMethodKind href "/Models/Profiles/Equipment/Enumerations/LocationMethodKind/"
style LocationMethodKind fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Switch : Switch.normalOpen
Switch : Switch.ratedCurrent
Switch : Switch.retained
ConductingEquipment : ConductingEquipment.BaseVoltage
Equipment : Equipment.aggregate
Equipment : Equipment.normallyInService
Equipment : Equipment.EquipmentContainer
PowerSystemResource : PowerSystemResource.locationMethodKind
PowerSystemResource : PowerSystemResource.AssetDataSheet
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.name
Inheritance
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
normalOpen | cim:Switch.normalOpen | 0..1 boolean | The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement the Discrete.normalValue is expected to match with the Switch.normalOpen. | Switch |
ratedCurrent | cim:Switch.ratedCurrent | 0..1 CurrentFlow | The maximum continuous current carrying capacity in amps governed by the device material and construction.The attribute shall be a positive value. | Switch |
retained | cim:Switch.retained | 0..1 boolean | Branch is retained in the topological solution. The flow through retained switches will normally be calculated in power flow. | Switch |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage | Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean | The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean | The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer | Container of this equipment. | Equipment |
locationMethodKind | nc-no:PowerSystemResource.locationMethodKind | 0..1 LocationMethodKind | Possible methods to derive geographical location. | PowerSystemResource |
AssetDataSheet | cim:PowerSystemResource.AssetDataSheet | 0..1 AssetInfo | Datasheet information for this power system resource. | PowerSystemResource |
mRID | cim:IdentifiedObject.mRID | 0..1 string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject |
description | cim:IdentifiedObject.description | 0..1 string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
name | cim:IdentifiedObject.name | 0..1 string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
Schema Source
- from schema: https://ap-no.cim4.eu/Equipment/1.0