Skip to content

EquivalentInjection

This class represents equivalent injections (generation or load). Voltage regulation is allowed only at the point of connection.

URI: cim:EquivalentInjection
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class EquivalentInjection
    click EquivalentInjection href "/Models/Profiles/Equipment/ConcreteClasses/EquivalentInjection/"
    style EquivalentInjection fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EquivalentEquipment <|-- EquivalentInjection : inherits
            click EquivalentEquipment href "/Models/Profiles/Equipment/AbstractClasses/EquivalentEquipment/"
            style EquivalentEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ConductingEquipment <|-- EquivalentEquipment : inherits
            click ConductingEquipment href "/Models/Profiles/Equipment/AbstractClasses/ConductingEquipment/"
            style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Equipment <|-- ConductingEquipment : inherits
            click Equipment href "/Models/Profiles/Equipment/AbstractClasses/Equipment/"
            style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        PowerSystemResource <|-- Equipment : inherits
            click PowerSystemResource href "/Models/Profiles/Equipment/AbstractClasses/PowerSystemResource/"
            style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- PowerSystemResource : inherits
            click IdentifiedObject href "/Models/Profiles/Equipment/AbstractClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EquivalentEquipment --> EquivalentNetwork : EquivalentEquipment.EquivalentNetwork

        EquivalentNetwork
            click EquivalentNetwork href "/Models/Profiles/Equipment/ConcreteClasses/EquivalentNetwork/"
            style EquivalentNetwork fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage

        BaseVoltage
            click BaseVoltage href "/Models/Profiles/Equipment/ConcreteClasses/BaseVoltage/"
            style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Equipment --> EquipmentContainer : Equipment.EquipmentContainer

        EquipmentContainer
            click EquipmentContainer href "/Models/Profiles/Equipment/AbstractClasses/EquipmentContainer/"
            style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        PowerSystemResource --> AssetInfo : PowerSystemResource.AssetDataSheet

        AssetInfo : Not defined in profile

        AssetInfo
            style AssetInfo fill:#A9A9A9,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment

        OperationalLimitSet
            click OperationalLimitSet href "/Models/Profiles/Equipment/ConcreteClasses/OperationalLimitSet/"
            style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Terminal --> ConductingEquipment : Terminal.ConductingEquipment

        Terminal
            click Terminal href "/Models/Profiles/Equipment/ConcreteClasses/Terminal/"
            style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        PowerSystemResource --> LocationMethodKind : PowerSystemResource.locationMethodKind

        LocationMethodKind
            click LocationMethodKind href "/Models/Profiles/Equipment/Enumerations/LocationMethodKind/"
            style LocationMethodKind fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EquivalentInjection : EquivalentInjection.maxP
        EquivalentInjection : EquivalentInjection.maxQ
        EquivalentInjection : EquivalentInjection.minP
        EquivalentInjection : EquivalentInjection.minQ
        EquivalentInjection : EquivalentInjection.regulationCapability
        EquivalentEquipment : EquivalentEquipment.EquivalentNetwork
        ConductingEquipment : ConductingEquipment.BaseVoltage
        Equipment : Equipment.aggregate
        Equipment : Equipment.normallyInService
        Equipment : Equipment.EquipmentContainer
        PowerSystemResource : PowerSystemResource.locationMethodKind
        PowerSystemResource : PowerSystemResource.AssetDataSheet
        IdentifiedObject : IdentifiedObject.mRID
        IdentifiedObject : IdentifiedObject.description
        IdentifiedObject : IdentifiedObject.name

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
maxP cim:EquivalentInjection.maxP 0..1 ActivePower Maximum active power of the injection. direct
maxQ cim:EquivalentInjection.maxQ 0..1 ReactivePower Maximum reactive power of the injection. Used for modelling of infeed for load flow exchange. Not used for short circuit modelling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used. direct
minP cim:EquivalentInjection.minP 0..1 ActivePower Minimum active power of the injection. direct
minQ cim:EquivalentInjection.minQ 0..1 ReactivePower Minimum reactive power of the injection. Used for modelling of infeed for load flow exchange. Not used for short circuit modelling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used. direct
regulationCapability cim:EquivalentInjection.regulationCapability 0..1 boolean Specifies whether or not the EquivalentInjection has the capability to regulate the local voltage. If true the EquivalentInjection can regulate. If false the EquivalentInjection cannot regulate. ReactiveCapabilityCurve can only be associated with EquivalentInjection if the flag is true. direct
EquivalentNetwork cim:EquivalentEquipment.EquivalentNetwork 0..1 EquivalentNetwork The equivalent where the reduced model belongs. EquivalentEquipment
BaseVoltage cim:ConductingEquipment.BaseVoltage 0..1 BaseVoltage Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. ConductingEquipment
aggregate cim:Equipment.aggregate 0..1 boolean The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. Equipment
normallyInService cim:Equipment.normallyInService 0..1 boolean The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1 EquipmentContainer Container of this equipment. Equipment
locationMethodKind nc-no:PowerSystemResource.locationMethodKind 0..1 LocationMethodKind Possible methods to derive geographical location. PowerSystemResource
AssetDataSheet cim:PowerSystemResource.AssetDataSheet 0..1 AssetInfo Datasheet information for this power system resource. PowerSystemResource
mRID cim:IdentifiedObject.mRID 0..1 string Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. IdentifiedObject
description cim:IdentifiedObject.description 0..1 string The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. IdentifiedObject
name cim:IdentifiedObject.name 0..1 string The name is any free human readable and possibly non unique text naming the object. IdentifiedObject

Schema Source