StationSupply
Station supply with load derived from the station output.
URI: cim:StationSupply
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class StationSupply
click StationSupply href "/Models/Profiles/Equipment/ConcreteClasses/StationSupply/"
style StationSupply fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConsumer <|-- StationSupply : inherits
click EnergyConsumer href "/Models/Profiles/Equipment/ConcreteClasses/EnergyConsumer/"
style EnergyConsumer fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConnection <|-- EnergyConsumer : inherits
click EnergyConnection href "/Models/Profiles/Equipment/AbstractClasses/EnergyConnection/"
style EnergyConnection fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment <|-- EnergyConnection : inherits
click ConductingEquipment href "/Models/Profiles/Equipment/AbstractClasses/ConductingEquipment/"
style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- ConductingEquipment : inherits
click Equipment href "/Models/Profiles/Equipment/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/Equipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/Equipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage
BaseVoltage
click BaseVoltage href "/Models/Profiles/Equipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/Equipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> AssetInfo : PowerSystemResource.AssetDataSheet
AssetInfo : Not defined in profile
AssetInfo
style AssetInfo fill:#A9A9A9,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/Equipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Terminal --> ConductingEquipment : Terminal.ConductingEquipment
Terminal
click Terminal href "/Models/Profiles/Equipment/ConcreteClasses/Terminal/"
style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource --> LocationMethodKind : PowerSystemResource.locationMethodKind
LocationMethodKind
click LocationMethodKind href "/Models/Profiles/Equipment/Enumerations/LocationMethodKind/"
style LocationMethodKind fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConsumer : EnergyConsumer.pfixed
EnergyConsumer : EnergyConsumer.pfixedPct
EnergyConsumer : EnergyConsumer.qfixed
EnergyConsumer : EnergyConsumer.qfixedPct
ConductingEquipment : ConductingEquipment.BaseVoltage
Equipment : Equipment.aggregate
Equipment : Equipment.normallyInService
Equipment : Equipment.EquipmentContainer
PowerSystemResource : PowerSystemResource.locationMethodKind
PowerSystemResource : PowerSystemResource.AssetDataSheet
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.name
Inheritance
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
pfixed | cim:EnergyConsumer.pfixed | 0..1 ActivePower | Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
pfixedPct | cim:EnergyConsumer.pfixedPct | 0..1 PerCent | Fixed active power as a percentage of load group fixed active power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
qfixed | cim:EnergyConsumer.qfixed | 0..1 ReactivePower | Reactive power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
qfixedPct | cim:EnergyConsumer.qfixedPct | 0..1 PerCent | Fixed reactive power as a percentage of load group fixed reactive power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage | Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean | The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. The aggregate attribute is used to indicate that the object is an aggregate of other objects. | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean | The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. The normallyInService attribute is used to indicate that the object is normally in service. | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer | Container of this equipment. | Equipment |
locationMethodKind | nc-no:PowerSystemResource.locationMethodKind | 0..1 LocationMethodKind | Possible methods to derive geographical location. | PowerSystemResource |
AssetDataSheet | cim:PowerSystemResource.AssetDataSheet | 0..1 AssetInfo | Datasheet information for this power system resource. | PowerSystemResource |
mRID | cim:IdentifiedObject.mRID | 0..1 string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject |
description | cim:IdentifiedObject.description | 0..1 string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
name | cim:IdentifiedObject.name | 0..1 string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
Schema Source
- from schema: https://ap-no.cim4.eu/Equipment/1.0