Skip to content

Terminal

An AC electrical connection point to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.

URI: cim:Terminal
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class Terminal
    click Terminal href "/Models/Profiles/Equipment/ConcreteClasses/Terminal/"
    style Terminal fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ACDCTerminal <|-- Terminal : inherits
            click ACDCTerminal href "/Models/Profiles/Equipment/AbstractClasses/ACDCTerminal/"
            style ACDCTerminal fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- ACDCTerminal : inherits
            click IdentifiedObject href "/Models/Profiles/Equipment/AbstractClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Terminal --> ConductingEquipment : Terminal.ConductingEquipment

        ConductingEquipment
            click ConductingEquipment href "/Models/Profiles/Equipment/AbstractClasses/ConductingEquipment/"
            style ConductingEquipment fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Terminal --> ConnectivityNode : Terminal.ConnectivityNode

        ConnectivityNode
            click ConnectivityNode href "/Models/Profiles/Equipment/ConcreteClasses/ConnectivityNode/"
            style ConnectivityNode fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        OperationalLimitSet --> ACDCTerminal : OperationalLimitSet.Terminal

        OperationalLimitSet
            click OperationalLimitSet href "/Models/Profiles/Equipment/ConcreteClasses/OperationalLimitSet/"
            style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RegulatingControl --> Terminal : RegulatingControl.Terminal

        RegulatingControl
            click RegulatingControl href "/Models/Profiles/Equipment/ConcreteClasses/RegulatingControl/"
            style RegulatingControl fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        TransformerEnd --> Terminal : TransformerEnd.Terminal

        TransformerEnd
            click TransformerEnd href "/Models/Profiles/Equipment/AbstractClasses/TransformerEnd/"
            style TransformerEnd fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Terminal --> PhaseCode : Terminal.phases

        PhaseCode
            click PhaseCode href "/Models/Profiles/Equipment/Enumerations/PhaseCode/"
            style PhaseCode fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Terminal : Terminal.phases
        Terminal : Terminal.ConductingEquipment
        Terminal : Terminal.ConnectivityNode
        ACDCTerminal : ACDCTerminal.sequenceNumber
        IdentifiedObject : IdentifiedObject.mRID
        IdentifiedObject : IdentifiedObject.description
        IdentifiedObject : IdentifiedObject.name

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
phases cim:Terminal.phases 0..1 PhaseCode Represents the normal network phasing condition. If the attribute is missing, three phases (ABC) shall be assumed, except for terminals of grounding classes (specializations of EarthFaultCompensator, GroundDisconnector, and Ground) which will be assumed to be N. Therefore, phase code ABCN is explicitly declared when needed, e.g. for star point grounding equipment.The phase code on terminals connecting same ConnectivityNode or same TopologicalNode as well as for equipment between two terminals shall be consistent. direct
ConductingEquipment cim:Terminal.ConductingEquipment 1..1 ConductingEquipment The conducting equipment of the terminal. Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes. direct
ConnectivityNode cim:Terminal.ConnectivityNode 0..1 ConnectivityNode The connectivity node to which this terminal connects with zero impedance. direct
sequenceNumber cim:ACDCTerminal.sequenceNumber 0..1 integer The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the starting point for a two terminal branch. ACDCTerminal
mRID cim:IdentifiedObject.mRID 0..1 string Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. IdentifiedObject
description cim:IdentifiedObject.description 0..1 string The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. IdentifiedObject
name cim:IdentifiedObject.name 0..1 string The name is any free human readable and possibly non unique text naming the object. IdentifiedObject

Schema Source