Skip to content

RotatingMachine

A rotating machine which may be used as a generator or motor.

*NOTE: this is an abstract class and should not be instantiated directly

URI: cim:RotatingMachine
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class RotatingMachine
    click RotatingMachine href "/Models/Profiles/CoreEquipment/AbstractClasses/RotatingMachine/"
    style RotatingMachine fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RotatingMachine <|-- AsynchronousMachine : inherits

        AsynchronousMachine
            click AsynchronousMachine href "/Models/Profiles/CoreEquipment/ConcreteClasses/AsynchronousMachine/"
            style AsynchronousMachine fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RotatingMachine <|-- SynchronousMachine : inherits

        SynchronousMachine
            click SynchronousMachine href "/Models/Profiles/CoreEquipment/ConcreteClasses/SynchronousMachine/"
            style SynchronousMachine fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RegulatingCondEq <|-- RotatingMachine : inherits
            click RegulatingCondEq href "/Models/Profiles/CoreEquipment/AbstractClasses/RegulatingCondEq/"
            style RegulatingCondEq fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EnergyConnection <|-- RegulatingCondEq : inherits
            click EnergyConnection href "/Models/Profiles/CoreEquipment/AbstractClasses/EnergyConnection/"
            style EnergyConnection fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ConductingEquipment <|-- EnergyConnection : inherits
            click ConductingEquipment href "/Models/Profiles/CoreEquipment/AbstractClasses/ConductingEquipment/"
            style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Equipment <|-- ConductingEquipment : inherits
            click Equipment href "/Models/Profiles/CoreEquipment/AbstractClasses/Equipment/"
            style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        PowerSystemResource <|-- Equipment : inherits
            click PowerSystemResource href "/Models/Profiles/CoreEquipment/AbstractClasses/PowerSystemResource/"
            style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- PowerSystemResource : inherits
            click IdentifiedObject href "/Models/Profiles/CoreEquipment/AbstractClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RotatingMachine --> GeneratingUnit : RotatingMachine.GeneratingUnit

        GeneratingUnit
            click GeneratingUnit href "/Models/Profiles/CoreEquipment/AbstractClasses/GeneratingUnit/"
            style GeneratingUnit fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        RotatingMachine --> HydroPump : RotatingMachine.HydroPump

        HydroPump
            click HydroPump href "/Models/Profiles/CoreEquipment/ConcreteClasses/HydroPump/"
            style HydroPump fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        RegulatingCondEq --> RegulatingControl : RegulatingCondEq.RegulatingControl

        RegulatingControl
            click RegulatingControl href "/Models/Profiles/CoreEquipment/ConcreteClasses/RegulatingControl/"
            style RegulatingControl fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage

        BaseVoltage
            click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
            style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        ConductingEquipment --> Terminal : ConductingEquipment.Terminals

        Terminal
            click Terminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/Terminal/"
            style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Equipment --> EquipmentContainer : Equipment.EquipmentContainer

        EquipmentContainer
            click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
            style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Equipment --> OperationalLimitSet : Equipment.OperationalLimitSet

        OperationalLimitSet
            click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
            style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        BaseVoltage --> ConductingEquipment : BaseVoltage.ConductingEquipment

        BaseVoltage
            click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
            style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EquipmentContainer --> Equipment : EquipmentContainer.Equipments

        EquipmentContainer
            click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
            style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        GeneratingUnit --> RotatingMachine : GeneratingUnit.RotatingMachine

        GeneratingUnit
            click GeneratingUnit href "/Models/Profiles/CoreEquipment/AbstractClasses/GeneratingUnit/"
            style GeneratingUnit fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        HydroPump --> RotatingMachine : HydroPump.RotatingMachine

        HydroPump
            click HydroPump href "/Models/Profiles/CoreEquipment/ConcreteClasses/HydroPump/"
            style HydroPump fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment

        OperationalLimitSet
            click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
            style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        RegulatingControl --> RegulatingCondEq : RegulatingControl.RegulatingCondEq

        RegulatingControl
            click RegulatingControl href "/Models/Profiles/CoreEquipment/ConcreteClasses/RegulatingControl/"
            style RegulatingControl fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Terminal --> ConductingEquipment : Terminal.ConductingEquipment

        Terminal
            click Terminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/Terminal/"
            style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white


        RotatingMachine : RotatingMachine.GeneratingUnit
        RotatingMachine : RotatingMachine.HydroPump
        RotatingMachine : RotatingMachine.ratedPowerFactor
        RotatingMachine : RotatingMachine.ratedS
        RotatingMachine : RotatingMachine.ratedU
        RegulatingCondEq : RegulatingCondEq.RegulatingControl
        ConductingEquipment : ConductingEquipment.BaseVoltage
        ConductingEquipment : ConductingEquipment.Terminals
        Equipment : Equipment.aggregate
        Equipment : Equipment.normallyInService
        Equipment : Equipment.EquipmentContainer
        Equipment : Equipment.OperationalLimitSet
        IdentifiedObject : IdentifiedObject.description
        IdentifiedObject : IdentifiedObject.energyIdentCodeEic
        IdentifiedObject : IdentifiedObject.mRID
        IdentifiedObject : IdentifiedObject.name
        IdentifiedObject : IdentifiedObject.shortName

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
GeneratingUnit cim:RotatingMachine.GeneratingUnit No cardinality available GeneratingUnit A synchronous machine may operate as a generator and as such becomes a member of a generating unit. direct
HydroPump cim:RotatingMachine.HydroPump No cardinality available HydroPump The synchronous machine drives the turbine which moves the water from a low elevation to a higher elevation. The direction of machine rotation for pumping may or may not be the same as for generating. direct
ratedPowerFactor cim:RotatingMachine.ratedPowerFactor No cardinality available float Power factor (nameplate data). It is primarily used for short circuit data exchange according to IEC 60909. The attribute cannot be a negative value. direct
ratedS cim:RotatingMachine.ratedS No cardinality available ApparentPower Nameplate apparent power rating for the unit.
The attribute shall have a positive value. direct
ratedU cim:RotatingMachine.ratedU No cardinality available Voltage Rated voltage (nameplate data, Ur in IEC 60909-0). It is primarily used for short circuit data exchange according to IEC 60909.
The attribute shall be a positive value. direct
RegulatingControl cim:RegulatingCondEq.RegulatingControl No cardinality available RegulatingControl The regulating control scheme in which this equipment participates. RegulatingCondEq
BaseVoltage cim:ConductingEquipment.BaseVoltage No cardinality available BaseVoltage Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. ConductingEquipment
Terminals cim:ConductingEquipment.Terminals No cardinality available Terminal Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes. ConductingEquipment
aggregate cim:Equipment.aggregate No cardinality available boolean The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine.
The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection. Equipment
normallyInService cim:Equipment.normallyInService No cardinality available boolean Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. Equipment
EquipmentContainer cim:Equipment.EquipmentContainer No cardinality available EquipmentContainer Container of this equipment. Equipment
OperationalLimitSet cim:Equipment.OperationalLimitSet No cardinality available OperationalLimitSet The operational limit sets associated with this equipment. Equipment
description cim:IdentifiedObject.description No cardinality available string The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. IdentifiedObject
energyIdentCodeEic eu:IdentifiedObject.energyIdentCodeEic No cardinality available string The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. IdentifiedObject
mRID cim:IdentifiedObject.mRID No cardinality available string Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. IdentifiedObject
name cim:IdentifiedObject.name No cardinality available string The name is any free human readable and possibly non unique text naming the object. IdentifiedObject
shortName eu:IdentifiedObject.shortName No cardinality available string The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. IdentifiedObject

Schema Source

Responsive Footer