DCShunt
A shunt device within the DC system, typically used for filtering. Needed for transient and short circuit studies.
URI: cim:DCShunt
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class DCShunt
click DCShunt href "/Models/Profiles/CoreEquipment/ConcreteClasses/DCShunt/"
style DCShunt fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
DCConductingEquipment <|-- DCShunt : inherits
click DCConductingEquipment href "/Models/Profiles/CoreEquipment/AbstractClasses/DCConductingEquipment/"
style DCConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- DCConductingEquipment : inherits
click Equipment href "/Models/Profiles/CoreEquipment/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/CoreEquipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/CoreEquipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
DCConductingEquipment --> DCTerminal : DCConductingEquipment.DCTerminals
DCTerminal
click DCTerminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/DCTerminal/"
style DCTerminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> OperationalLimitSet : Equipment.OperationalLimitSet
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
DCTerminal --> DCConductingEquipment : DCTerminal.DCConductingEquipment
DCTerminal
click DCTerminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/DCTerminal/"
style DCTerminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EquipmentContainer --> Equipment : EquipmentContainer.Equipments
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
DCShunt : DCShunt.capacitance
DCShunt : DCShunt.resistance
DCConductingEquipment : DCConductingEquipment.ratedUdc
DCConductingEquipment : DCConductingEquipment.DCTerminals
Equipment : Equipment.aggregate
Equipment : Equipment.normallyInService
Equipment : Equipment.EquipmentContainer
Equipment : Equipment.OperationalLimitSet
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.energyIdentCodeEic
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.name
IdentifiedObject : IdentifiedObject.shortName
Inheritance
Attributes
| Name | URI | Cardinality and Range | Description | Inheritance |
|---|---|---|---|---|
| capacitance | cim:DCShunt.capacitance | No cardinality available Capacitance | Capacitance of the DC shunt. | direct |
| resistance | cim:DCShunt.resistance | No cardinality available Resistance | Resistance of the DC device. | direct |
| ratedUdc | cim:DCConductingEquipment.ratedUdc | No cardinality available Voltage | Rated DC device voltage. The attribute shall be a positive value. It is configuration data used in power flow. | DCConductingEquipment |
| DCTerminals | cim:DCConductingEquipment.DCTerminals | No cardinality available DCTerminal | A DC conducting equipment has DC terminals. | DCConductingEquipment |
| aggregate | cim:Equipment.aggregate | No cardinality available boolean | The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. | |
| The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection. | Equipment | |||
| normallyInService | cim:Equipment.normallyInService | No cardinality available boolean | Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. | Equipment |
| EquipmentContainer | cim:Equipment.EquipmentContainer | No cardinality available EquipmentContainer | Container of this equipment. | Equipment |
| OperationalLimitSet | cim:Equipment.OperationalLimitSet | No cardinality available OperationalLimitSet | The operational limit sets associated with this equipment. | Equipment |
| description | cim:IdentifiedObject.description | No cardinality available string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | No cardinality available string | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. | IdentifiedObject |
| mRID | cim:IdentifiedObject.mRID | No cardinality available string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. | |
| For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject | |||
| name | cim:IdentifiedObject.name | No cardinality available string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
| shortName | eu:IdentifiedObject.shortName | No cardinality available string | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. | IdentifiedObject |