VoltageLevel
A collection of equipment at one common system voltage forming a switchgear. The equipment typically consists of breakers, busbars, instrumentation, control, regulation and protection devices as well as assemblies of all these.
URI: cim:VoltageLevel
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class VoltageLevel
click VoltageLevel href "/Models/Profiles/CoreEquipment/ConcreteClasses/VoltageLevel/"
style VoltageLevel fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EquipmentContainer <|-- VoltageLevel : inherits
click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConnectivityNodeContainer <|-- EquipmentContainer : inherits
click ConnectivityNodeContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/ConnectivityNodeContainer/"
style ConnectivityNodeContainer fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- ConnectivityNodeContainer : inherits
click PowerSystemResource href "/Models/Profiles/CoreEquipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/CoreEquipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
VoltageLevel --> BaseVoltage : VoltageLevel.BaseVoltage
BaseVoltage
click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
VoltageLevel --> Bay : VoltageLevel.Bays
Bay
click Bay href "/Models/Profiles/CoreEquipment/ConcreteClasses/Bay/"
style Bay fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
VoltageLevel --> Substation : VoltageLevel.Substation
Substation
click Substation href "/Models/Profiles/CoreEquipment/ConcreteClasses/Substation/"
style Substation fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EquipmentContainer --> Equipment : EquipmentContainer.Equipments
Equipment
click Equipment href "/Models/Profiles/CoreEquipment/AbstractClasses/Equipment/"
style Equipment fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConnectivityNodeContainer --> ConnectivityNode : ConnectivityNodeContainer.ConnectivityNodes
ConnectivityNode
click ConnectivityNode href "/Models/Profiles/CoreEquipment/AbstractClasses/ConnectivityNode/"
style ConnectivityNode fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
BaseVoltage --> VoltageLevel : BaseVoltage.VoltageLevel
BaseVoltage
click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Bay --> VoltageLevel : Bay.VoltageLevel
Bay
click Bay href "/Models/Profiles/CoreEquipment/ConcreteClasses/Bay/"
style Bay fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConnectivityNode --> ConnectivityNodeContainer : ConnectivityNode.ConnectivityNodeContainer
ConnectivityNode
click ConnectivityNode href "/Models/Profiles/CoreEquipment/AbstractClasses/ConnectivityNode/"
style ConnectivityNode fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
Equipment
click Equipment href "/Models/Profiles/CoreEquipment/AbstractClasses/Equipment/"
style Equipment fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Substation --> VoltageLevel : Substation.VoltageLevels
Substation
click Substation href "/Models/Profiles/CoreEquipment/ConcreteClasses/Substation/"
style Substation fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
VoltageLevel : VoltageLevel.BaseVoltage
VoltageLevel : VoltageLevel.Bays
VoltageLevel : VoltageLevel.Substation
VoltageLevel : VoltageLevel.highVoltageLimit
VoltageLevel : VoltageLevel.lowVoltageLimit
EquipmentContainer : EquipmentContainer.Equipments
ConnectivityNodeContainer : ConnectivityNodeContainer.ConnectivityNodes
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.energyIdentCodeEic
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.name
IdentifiedObject : IdentifiedObject.shortName
Inheritance
Attributes
| Name | URI | Cardinality and Range | Description | Inheritance |
|---|---|---|---|---|
| BaseVoltage | cim:VoltageLevel.BaseVoltage | No cardinality available BaseVoltage | The base voltage used for all equipment within the voltage level. | direct |
| Bays | cim:VoltageLevel.Bays | No cardinality available Bay | The bays within this voltage level. | direct |
| Substation | cim:VoltageLevel.Substation | No cardinality available Substation | The substation of the voltage level. | direct |
| highVoltageLimit | cim:VoltageLevel.highVoltageLimit | No cardinality available Voltage | The bus bar's high voltage limit. | |
| The limit applies to all equipment and nodes contained in a given VoltageLevel. It is not required that it is exchanged in pair with lowVoltageLimit. It is preferable to use operational VoltageLimit, which prevails, if present. | direct | |||
| lowVoltageLimit | cim:VoltageLevel.lowVoltageLimit | No cardinality available Voltage | The bus bar's low voltage limit. | |
| The limit applies to all equipment and nodes contained in a given VoltageLevel. It is not required that it is exchanged in pair with highVoltageLimit. It is preferable to use operational VoltageLimit, which prevails, if present. | direct | |||
| Equipments | cim:EquipmentContainer.Equipments | No cardinality available Equipment | Contained equipment. | EquipmentContainer |
| ConnectivityNodes | cim:ConnectivityNodeContainer.ConnectivityNodes | No cardinality available ConnectivityNode | Connectivity nodes which belong to this connectivity node container. | ConnectivityNodeContainer |
| description | cim:IdentifiedObject.description | No cardinality available string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | No cardinality available string | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. | IdentifiedObject |
| mRID | cim:IdentifiedObject.mRID | No cardinality available string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. | |
| For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject | |||
| name | cim:IdentifiedObject.name | No cardinality available string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
| shortName | eu:IdentifiedObject.shortName | No cardinality available string | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. | IdentifiedObject |