ExternalNetworkInjection
This class represents the external network and it is used for IEC 60909 calculations.
URI: cim:ExternalNetworkInjection
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class ExternalNetworkInjection
click ExternalNetworkInjection href "/Models/Profiles/ShortCircuit/ConcreteClasses/ExternalNetworkInjection/"
style ExternalNetworkInjection fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
RegulatingCondEq <|-- ExternalNetworkInjection : inherits
click RegulatingCondEq href "/Models/Profiles/ShortCircuit/AbstractClasses/RegulatingCondEq/"
style RegulatingCondEq fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConnection <|-- RegulatingCondEq : inherits
click EnergyConnection href "/Models/Profiles/ShortCircuit/AbstractClasses/EnergyConnection/"
style EnergyConnection fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment <|-- EnergyConnection : inherits
click ConductingEquipment href "/Models/Profiles/ShortCircuit/AbstractClasses/ConductingEquipment/"
style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- ConductingEquipment : inherits
click Equipment href "/Models/Profiles/ShortCircuit/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/ShortCircuit/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/ShortCircuit/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ExternalNetworkInjection : ExternalNetworkInjection.ikSecond
ExternalNetworkInjection : ExternalNetworkInjection.maxInitialSymShCCurrent
ExternalNetworkInjection : ExternalNetworkInjection.maxR0ToX0Ratio
ExternalNetworkInjection : ExternalNetworkInjection.maxR1ToX1Ratio
ExternalNetworkInjection : ExternalNetworkInjection.maxZ0ToZ1Ratio
ExternalNetworkInjection : ExternalNetworkInjection.minInitialSymShCCurrent
ExternalNetworkInjection : ExternalNetworkInjection.minR0ToX0Ratio
ExternalNetworkInjection : ExternalNetworkInjection.minR1ToX1Ratio
ExternalNetworkInjection : ExternalNetworkInjection.minZ0ToZ1Ratio
ExternalNetworkInjection : ExternalNetworkInjection.voltageFactor
IdentifiedObject : IdentifiedObject.mRID
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EnergyConnection
- RegulatingCondEq
- ExternalNetworkInjection
- RegulatingCondEq
- EnergyConnection
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
| Name | URI | Cardinality and Range | Description | Inheritance |
|---|---|---|---|---|
| ikSecond | cim:ExternalNetworkInjection.ikSecond | No cardinality available boolean | Indicates whether initial symmetrical short-circuit current and power have been calculated according to IEC (Ik"). Used only if short circuit calculations are done according to superposition method. | direct |
| maxInitialSymShCCurrent | cim:ExternalNetworkInjection.maxInitialSymShCCurrent | No cardinality available CurrentFlow | Maximum initial symmetrical short-circuit currents (Ik" max) in A (Ik" = Sk"/(SQRT(3) Un)). Used for short circuit data exchange according to IEC 60909. | direct |
| maxR0ToX0Ratio | cim:ExternalNetworkInjection.maxR0ToX0Ratio | No cardinality available float | Maximum ratio of zero sequence resistance of Network Feeder to its zero sequence reactance (R(0)/X(0) max). Used for short circuit data exchange according to IEC 60909. | direct |
| maxR1ToX1Ratio | cim:ExternalNetworkInjection.maxR1ToX1Ratio | No cardinality available float | Maximum ratio of positive sequence resistance of Network Feeder to its positive sequence reactance (R(1)/X(1) max). Used for short circuit data exchange according to IEC 60909. | direct |
| maxZ0ToZ1Ratio | cim:ExternalNetworkInjection.maxZ0ToZ1Ratio | No cardinality available float | Maximum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) max). Used for short circuit data exchange according to IEC 60909. | direct |
| minInitialSymShCCurrent | cim:ExternalNetworkInjection.minInitialSymShCCurrent | No cardinality available CurrentFlow | Minimum initial symmetrical short-circuit currents (Ik" min) in A (Ik" = Sk"/(SQRT(3) Un)). Used for short circuit data exchange according to IEC 60909. | direct |
| minR0ToX0Ratio | cim:ExternalNetworkInjection.minR0ToX0Ratio | No cardinality available float | Indicates whether initial symmetrical short-circuit current and power have been calculated according to IEC (Ik"). Used for short circuit data exchange according to IEC 6090. | direct |
| minR1ToX1Ratio | cim:ExternalNetworkInjection.minR1ToX1Ratio | No cardinality available float | Minimum ratio of positive sequence resistance of Network Feeder to its positive sequence reactance (R(1)/X(1) min). Used for short circuit data exchange according to IEC 60909. | direct |
| minZ0ToZ1Ratio | cim:ExternalNetworkInjection.minZ0ToZ1Ratio | No cardinality available float | Minimum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) min). Used for short circuit data exchange according to IEC 60909. | direct |
| voltageFactor | cim:ExternalNetworkInjection.voltageFactor | No cardinality available PU | Voltage factor in pu, which was used to calculate short-circuit current Ik" and power Sk". Used only if short circuit calculations are done according to superposition method. | direct |
| mRID | cim:IdentifiedObject.mRID | No cardinality available string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. | |
| For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject |